Sorbent Tube, Anasorb CSC, Coconut Charcoal, 8 x 110-mm size, 2 sections, 200/400 mg sorbent, 20/40 mesh, with GS ends and FWW separators, fits Type B tube cover, pk/50
Sorbent tube sampling is the NIOSH/OSHA approved method for collecting most hazardous gases and vapors from the air. Federal law has established permissible exposure limits (PELs) for workers' exposures to a variety of airborne chemical hazards. These limits are specified in several ways: eight-hour time-weighted averages (TWAs), Short-Term Exposure Limits (STELs), and Ceiling values. Eight-hour TWA limits are specified for full-shift exposures. STELs are usually issued as 15-minute exposure limits and Ceiling values are issued as peak levels not to be exceeded at any time during the working day. Sorbent tubes have been established as a reliable tool for each of these sampling requirements.
美國SKC活性碳吸附管
在所有NIOSH、OSHA標(biāo)準(zhǔn)分析方法中測(cè)定空氣中有害化學(xué)物及其蒸氣的方法,大多數(shù)是以吸附管作為采樣介質(zhì)訂定的,因此吸附管是職業(yè)衛(wèi)生和環(huán)境保護(hù)空氣采樣的要素及基石。
SKC吸附管的制造與研究發(fā)展已有30年以上經(jīng)驗(yàn),目前是世界最大的吸附管制造商,所有的吸附管皆以NIOSH、OSHA、EPA、或HSE所公告的規(guī)范所制造。SKC所制造的吸附管種類約有150種以上,可供800種以上化學(xué)物采樣測(cè)試,提供使用者多樣化的選擇。如何選擇則請(qǐng)?jiān)斠奛IOSH、OSHA、EPA、或HSE所公告的空氣采樣分析方法指引,或參閱SKC英文綜合目錄的索引表。其吸附管內(nèi)之固體吸附劑介質(zhì)種類繁多,例如較常見的活性碳管,硅膠管,XAD-2管等。尚有在固體介質(zhì)上披覆一些化學(xué)物介質(zhì)可有效捕集空氣中特定有害化學(xué)物,以替代沖擊瓶的液體采樣方法。
活性碳吸附管 50/100mg 226-01 50支
活性碳吸附管 50/100mg 226-01-BULK 1000支
活性碳吸附管 200/400mg 226-09 50支
活性碳吸附管 200/400mg 226-09-BULK 1000支
硅膠吸附管 75/150mg 226-10 50支
硅膠吸附管 200/400mg 226-10-03 50支 7mm外徑,110mm長 (適用于無機(jī)酸類采樣)
Anasorb CMS 吸附管 75/150mg 226-121 20支
Tenax 吸附管 50/100mg 226-35-03 50支 8mm外徑,110mm長
硅膠吸附管 50/100mg 226-51 50支
商品評(píng)論
(已有0條評(píng)論)購買流程
1.購買產(chǎn)品:點(diǎn)擊“立即購買”→填寫產(chǎn)品數(shù)量、聯(lián)系方式并提交→會(huì)員顧問訂單處理→合同簽訂。
2.咨詢產(chǎn)品:請(qǐng)聯(lián)系會(huì)員顧問或致電會(huì)員客服電話。
3.如果您還不是我們的會(huì)員,請(qǐng)先注冊(cè)。
4.最小起訂數(shù)量:1 ,進(jìn)口產(chǎn)品貨期,請(qǐng)跟產(chǎn)品擔(dān)當(dāng)聯(lián)系!
品牌擔(dān)當(dāng):
投訴電話:17717909117
聯(lián)系方式: 電話:021-52069907 分機(jī) 或撥0轉(zhuǎn)總機(jī),傳真:010-52060857
維修流程
- 1、技術(shù)溝通,初步判斷問題電話,與客戶進(jìn)行初步溝通、了解并初步判斷儀器所出現(xiàn)的故障問題。
- 2、簽訂維修協(xié)議由我公司向客戶發(fā)送儀器維修協(xié)議,客戶需如實(shí)填寫內(nèi)容并回傳以便我司對(duì)儀器做進(jìn)一步判斷。
- 3、客戶郵寄儀器客戶可按照我司地址郵寄儀器,并將快遞單拍照發(fā)送至您的專屬客服進(jìn)行備案。
- 4、詳細(xì)診斷機(jī)器故障我司收到郵寄儀器后會(huì)對(duì)郵寄的儀器進(jìn)行拍照并開箱檢驗(yàn),對(duì)儀器做進(jìn)一步故障判斷。
- 5、支付維修費(fèi)用如客戶儀器在保修期內(nèi),我司不收取任何維修費(fèi),如客戶儀器在保修期外,我司會(huì)適當(dāng)收取維修費(fèi)。
- 6、郵寄儀器給客戶我司將維修好的儀器按客戶地址進(jìn)行拍照并郵寄,自此雖維修協(xié)議終止,但我司將提供終身免費(fèi)答疑及技術(shù)指導(dǎo)。
Testo 340 煙氣分析儀 | Testo350 煙氣分析儀 | PMS塵埃粒子計(jì)數(shù)器 | TSI塵埃粒子計(jì)數(shù)器 | Lighthouse塵埃粒子計(jì)數(shù)器 | Metone塵埃粒子計(jì)數(shù)器 |
HACH塵埃粒子計(jì)數(shù)器 | TSI氣溶膠發(fā)生器 | ATI氣溶膠發(fā)生器 | Palas氣溶膠發(fā)生器 | Topas氣溶膠發(fā)生器 | Palas靜電中和器 |
Topas靜電中和器 | Grimm粒徑譜儀 | TSI粒徑譜儀 | Topas粒徑譜儀 | Palas粒徑譜儀 | TSI掃描電遷移率粒徑譜儀 |
HTV 甲醛檢測(cè)儀 | HTV-M甲醛檢測(cè)儀 | TVOC 檢測(cè)儀維修 | Grimm掃描電遷移率粒徑譜儀 | Palas掃描電遷移率粒徑譜儀 | Brechtel掃描電遷移率粒徑譜儀 |
TSI 8530粉塵儀 | TSI 8532粉塵儀 | TSI 8533粉塵儀 | Rad7 氡檢測(cè)儀 | TSI 8534粉塵儀 | Thermo PDR-1500粉塵儀 |
ATI 2i光度計(jì) | ATI氣溶膠稀釋器 | 風(fēng)量罩 | 風(fēng)速儀 | 空氣品質(zhì)檢測(cè)儀 | EN779測(cè)試臺(tái)改造 |
Dustmate 粉塵儀 | TSI 8108大顆粒氣溶膠發(fā)生器 | TSI 3450單分散氣溶膠發(fā)生器 | 車身氣密性檢測(cè)設(shè)備 | 風(fēng)管漏風(fēng)量測(cè)試設(shè)備 | 凝聚核粒子計(jì)數(shù)器校準(zhǔn)裝置 |
粒子計(jì)數(shù)器校準(zhǔn)裝置 | 更多型號(hào)請(qǐng)咨詢客服19mro@19mro.com |